Centrifugal Water Chiller Double Unit

The ejector pump is used to recovery oil in low pressure side by medium pressure flash gas, without energy loss on water chiller.

Price Interview

Price Interview

Centrifugal Water Chiller Double Unit

Interview

Select the number of specifications

Please check the product information you want!

Product Detail

SANHER Centrifugal Water Chiller (double Unit)

Profile

● Cooling capacity of Sanher double unit centrifugal water chiller from 1500 to 2800 ton.

● Brand: SANHER or OEM

● Running Condition:

Evaporator: Water inlet/outlet temperature is 12℃/7℃

Condenser: Water inlet/outlet temperature is 30℃/35℃ (When running conditions different, please contact with us for detail parameter)

● The power supply options:

Low-voltage unit: 3φ-380V-50Hz

High- voltage unit: 3φ-6KV-50Hz,3φ-6.6KV-50Hz,3φ-10KV-50Hz


1(001)

 

Features and Advantages

1.Professional design

SANHER centrifugal chiller adopts Hanbell 2 stage centrifugal chiller.

2(001)

3

2.Reliable oil reclaim device-ejector pump

The ejector pump is used to recovery oil in low pressure side by medium pressure flash gas, without energy loss on water chiller.

4

3.Control components of refrigerant flow -orifice plate.

(1)Orifice plate is adopted as the refrigerant flow control device. Each orifice plate is designed in accordance with the unit's performance and reaches the most match of the unit.

(2)2-3 orifice plates are adopted as a set of throttling device. The first one is used as liquid seal and the rest are used to throttle and pressure drop, in order to adjust the refrigerant flow that the evaporator required , by the dynamic balance of refrigerant itself at full load, partial load and different conditions.

(3)As there are no moving parts of the orifice plate, its reliability is much better than all kinds of throttling valves of mechanical transmission.

5(001) 6(001)

When full load operation, liquid column height is H, and the static pressure generated by liquid column will deliver refrigerant required from the first orifice plate to the second one.

When half load operation, liquid column height is H/4, and the when refrigerant through the first orifice plate becomes half because of insufficient static pressure. There is flash phenomenon between two orifice plates generated by the up steam flow reduction. The refrigerant flow will decrease by half as liquid refrigerant mixed with large amount of flashing gas through the second orifice plate together.

 

Packing and Shipping

Plastic film+ Wooden box for exporting.

Ship by sea or by land


No comment

Product Detail

SANHER Centrifugal Water Chiller (double Unit)

Profile

● Cooling capacity of Sanher double unit centrifugal water chiller from 1500 to 2800 ton.

● Brand: SANHER or OEM

● Running Condition:

Evaporator: Water inlet/outlet temperature is 12℃/7℃

Condenser: Water inlet/outlet temperature is 30℃/35℃ (When running conditions different, please contact with us for detail parameter)

● The power supply options:

Low-voltage unit: 3φ-380V-50Hz

High- voltage unit: 3φ-6KV-50Hz,3φ-6.6KV-50Hz,3φ-10KV-50Hz


1(001)

 

Features and Advantages

1.Professional design

SANHER centrifugal chiller adopts Hanbell 2 stage centrifugal chiller.

2(001)

3

2.Reliable oil reclaim device-ejector pump

The ejector pump is used to recovery oil in low pressure side by medium pressure flash gas, without energy loss on water chiller.

4

3.Control components of refrigerant flow -orifice plate.

(1)Orifice plate is adopted as the refrigerant flow control device. Each orifice plate is designed in accordance with the unit's performance and reaches the most match of the unit.

(2)2-3 orifice plates are adopted as a set of throttling device. The first one is used as liquid seal and the rest are used to throttle and pressure drop, in order to adjust the refrigerant flow that the evaporator required , by the dynamic balance of refrigerant itself at full load, partial load and different conditions.

(3)As there are no moving parts of the orifice plate, its reliability is much better than all kinds of throttling valves of mechanical transmission.

5(001) 6(001)

When full load operation, liquid column height is H, and the static pressure generated by liquid column will deliver refrigerant required from the first orifice plate to the second one.

When half load operation, liquid column height is H/4, and the when refrigerant through the first orifice plate becomes half because of insufficient static pressure. There is flash phenomenon between two orifice plates generated by the up steam flow reduction. The refrigerant flow will decrease by half as liquid refrigerant mixed with large amount of flashing gas through the second orifice plate together.

 

Packing and Shipping

Plastic film+ Wooden box for exporting.

Ship by sea or by land


Centrifugal Water Chiller Double Unit
The ejector pump is used to recovery oil in low pressure side by medium pressure flash gas, without energy loss on water chiller.
Long press to look detail
Long by picture save/share
INQUIRY

ONLINE INQUIRY MORE+
  • Contacts *

  • Mobile phone *

  • Information

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

Centrifugal Water Chiller Double Unit

Enquiry
INQUIRY

ONLINE INQUIRY MORE+
  • Contacts *

  • Mobile phone *

  • Information

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

Related Products

Ultrasonic metal welding machine-wire harness welding

Ultrasonic metal welding machine-wire harness welding

The JHN Sonic Ultrasonic Metal Welding Machine represents the pinnacle of industrial wire harness welding technology. Designed for heavy-duty manufacturing, this advanced system features a powerful output range of 12000W to 15000W, making it capable of handling substantial wire cross-sections with ease. Controlled by an industrial PC and equipped with advanced ultrasonic welding technology, the machine ensures precise, automated, and consistent performance.
Ultrasonic metal welding machine - wire harness terminal welding machine/double push  ultrasonic welding machine

Ultrasonic metal welding machine - wire harness terminal welding machine/double push ultrasonic welding machine

The JHN Sonic Ultrasonic Metal Welding Machine is a heavy-duty industrial solution designed specifically for high-quality wire harness terminal welding. Available in both standard and Double Push configurations, this series combines robust mechanical engineering with precise digital control. The machine features a high-precision upper and lower machine head with an X-guide rail German structure, ensuring exceptional stability and mechanical performance during high-volume production.
Ultrasonic metal welding machine wire harness welding

Ultrasonic metal welding machine wire harness welding

The JHN Sonic Ultrasonic Metal Welding Machine for wire harnesses is a versatile and robust solution designed for the electrical and automotive industries. Utilizing advanced ultrasonic technology, this machine delivers precise and durable welds for various wire configurations. It is engineered to handle a wide range of wire cross-sections, ensuring that every connection—from simple single wires to complex multi-wire bundles—is welded with superior strength and conductivity.
Ultrasonic metal welding machine DP direct pressure welding machine

Ultrasonic metal welding machine DP direct pressure welding machine

The JHN Sonic DP (Direct Pressure) Ultrasonic Metal Welding Machine is a high-performance industrial solution designed for precision battery manufacturing. Featuring a Smart Digital Display, this machine allows for intuitive monitoring and control of the welding process. It utilizes advanced direct pressure technology to weld multi-layer copper and aluminum foils directly to electrode ears (tabs).

OUR PARTNERS

Room 204, 2nd Floor, Factory Building,

No. 6 Taipingyang 1st Road,

Xingtang Town, Zengcheng District, Guangzhou City

 

Copyright © 2005-2015 MySite Ltd. All Rights Reserved.

Service Center
Phone number
+86 157 1812 4557
WhatsApp
Andy:+86 157 1812 4557
WeChat
GLtec1
Qrcode
WeChat
Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.